Johnson-level-tool-mfg 40-6006 Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
©2013 Johnson Level & Tool - Rev. 1 15
Error Codes
Code Description Solution
Err01
Distance is outside of measuring range
Measure in a shorter
distance or longer distance
Err02 Reflected signal is too weak Measure a better surface
Err03 Out of display range Maximum Value: 99,999
Split up measurement area
into smaller segments.
Err04
Pythagorean theorem calculation error
Check and verify value or the
sequence of measurements
is correct
Err05 Low Battery Install a new battery
Err06
Temperature is outside of working range
Measure in an environment
within
specified working
temperature range
Err07 Ambient light is too strong Measure in a darker place
(shadow target)
Measurement Errors
Error messages will appear if the unit’s receiver is not getting a
sufficient laser return signal.
Common surfaces that could cause an error reading:
- Water or other fluids
- Translucent to clear surfaces like glass or acrylic
- Porous or dark surfaces may require longer reading times or
cause an error reading
- Moving surfaces or objects such as curtains
- Highly reflective or angled surfaces may deflect the laser
beam signal
7349H-English_Manuals 9/6/13 1:55 PM Page 15
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20

Comentarios a estos manuales

Sin comentarios